Energy
S. A. Gandjalikhan Nassab
Abstract
This paper deals with the development of compound parabolic collectors (CPCs), utilizing a partial glass sheet adjacent to the absorber plate for the purpose of performance improvement. The collector under study has a parabolic shape, whose cavity is filled with air and the turbulent natural convection ...
Read More
This paper deals with the development of compound parabolic collectors (CPCs), utilizing a partial glass sheet adjacent to the absorber plate for the purpose of performance improvement. The collector under study has a parabolic shape, whose cavity is filled with air and the turbulent natural convection takes place because of the air density gradient. The main goal is the reduction of heat losses by keeping away the high-temperature region near to the absorber from the main recirculaetd convection airflow by installation of a separating glass sheet. The conservations of mass, momentum and energy as the set of governing equations for the steady and turbulent free convection airflow in the CPC’s cavity and the Laplace equation for computation of temperature distributions in solid parts including the glass cover, absorber plate, and glass sheet were numerically solved by the finite element method. The COMSOL Multiphysics software was used for the present simulation. For the computation of turbulent stress and heat flux, the κ-ε turbulence model was employed. An attempt was made to investigate the installation of a fully transparent glass sheet near the absorber plate on the thermal behavior of the studied CPC. It is expected that this factor leads to lowering the heat losses from boundary surfaces, especially from the glass cover. Numerical findings showed about a 24% increase in the efficiency of studied test cases because of the installed glass sheet. Comparison between the theoretical findings with experiment shows good consistency.
S. A. Gandjalikhan Nassab; M. Moein Addini
Abstract
In the present paper, the use of radiating gas instead of air inside the cavity of compound parabolic collectors (CPSs) is suggested and verified by numerical analysis. The collector under study has a simple cone shape with flat absorber which is filled with a participating gas such as carbon dioxide ...
Read More
In the present paper, the use of radiating gas instead of air inside the cavity of compound parabolic collectors (CPSs) is suggested and verified by numerical analysis. The collector under study has a simple cone shape with flat absorber which is filled with a participating gas such as carbon dioxide instead of air for the purpose of increasing the thermal performance. In numerical simulation, the continuity, momentum and energy equations for the steady natural convection laminar gas flow in the CPC’s cavity and the conduction equation for glass cover and absorber plate were solved by the finite element method (FEM) using the COMSOL multi-physics. Because of the radiative term in the gas energy equation, the intensity of radiation in participating gas flow should be computed. Toward this end, the radiative transfer equation (RTE) was solved by the discrete ordinate method (DOM), considering both diffuse and collimated radiations. The approximation was employed in calculation of the diffuse part of radiation. It was observed that the gas radiation causes high temperature with more uniform distribution inside the cavity of collector. Also, numerical results reveal more than 3% increase in the rate of heat transfer from absorber surface into working fluid and hence a desired performance for the collector because of the gas radiation effect. Comparison between the present numerical results with theoretical and experimental data reported in the literature showed good consistency.