TY - JOUR ID - 141264 TI - The Role of Nanoparticles and Different Tube Diameter on Thermal Performance in Shell and Helically Coiled Tube Heat Exchangers with Single Phase and Sub-cooled Boiling Flow JO - Iranica Journal of Energy & Environment JA - IJEE LA - en SN - 2079-2115 AU - Abazari Bahnemiri, H. AU - Oloomi, S. A. A. AU - Mirjalily, S. A. A. AU - Zare-Shahabadi, A. AD - Department of Mechanical Engineering, Yazd Branch, Islamic Azad University, Yazd, Iran AD - Department of Mechanical Engineering,Technical and Vocational University (TVU), Tehran, Iran Y1 - 2021 PY - 2021 VL - 12 IS - 4 SP - 367 EP - 377 KW - heat exchanger KW - Heat Transfer Coefficient KW - Helically coiled tube KW - Nanoparticles KW - Sub-cooled boiling flow DO - 10.5829/ijee.2021.12.04.10 N2 - In the present research, effects of nanoparticles and changing of tube diameter have been scrutinized on heat transfer parameters in the shell and helically coiled tube heat exchanger. A CFD analysis and also a modeling of the mentioned heat exchager have carried out by writing a code in MATLAB software for two regimes involving forced convection heat trasnfer in single phase fluid flow and sub-cooled boiling. In the case under analysis, considered nanoparticles in this research was Nickel nanoparticles with 0.1 and 1% volumetric concentration. Based on the results, both going up of volume concentration of nanoparticles and increasing of tube diameter are cause to make better heat transfer parameters. In truth, heat transfer coefficient and Nusselt number have been enhanced by 0.1 and 1 % volumetric concentration of Nickel nanoparticles. UR - https://www.ijee.net/article_141264.html L1 - https://www.ijee.net/article_141264_6afeb11559b4357c4688130ab49b3bda.pdf ER -