Neda Daei parizi; Mansour Nikpour; Hossein Fallah
Articles in Press, Accepted Manuscript, Available Online from 17 April 2024
Abstract
For reading and writing in classrooms therefore a lot of energy is consumed in educational spaces. Limitation of fossil fuels and environmental pollution are two subjects that demonstrate the importance and significance of the present study. Previous studies show that window size and configuration have ...
Read More
For reading and writing in classrooms therefore a lot of energy is consumed in educational spaces. Limitation of fossil fuels and environmental pollution are two subjects that demonstrate the importance and significance of the present study. Previous studies show that window size and configuration have a significant effect on daylight quality but numbers and the ways of expansion of windows in horizontal and vertical directions of the wall have not been investigated in classrooms in hot and arid regions of Kerman city. The objective of this paper is to evaluate the daylight indicators in different classrooms when different numbers of windows (from 1 window to 5 windows) are applied both horizontal and vertical expansion in each window area from (10%c WWR to 60% WWR). This research has been done through the simulation of different classrooms in Design Builder software under Kerman weather data. Validation of Design Builder has been evaluated through experimental measurement of two actual classrooms and comparing the simulation results and experimental data. The findings of this research demonstrated that using a greater number of windows in classrooms causes a decrease in the amount of daylight penetrating the classrooms.
Energy
M. Movehhedi Nia; M. Nikpour; E. Jahanshahi Javaran
Abstract
The research aims to develop sustainable daylighting strategies for contemporary buildings by drawing inspiration from traditional vernacular housing solutions. In this study, the daylight factors of a contemporary residential space with a central courtyard which is located in Kerman, Iran is evaluated. ...
Read More
The research aims to develop sustainable daylighting strategies for contemporary buildings by drawing inspiration from traditional vernacular housing solutions. In this study, the daylight factors of a contemporary residential space with a central courtyard which is located in Kerman, Iran is evaluated. After modeling the building in Design Builder software, the U-values of the external walls, roof, floor and windows based on the available materials in the market of Iran are calculated. The results of daylight simulations are presented in term of Average DF (%), Work plane Illuminanace (Lux) and Uniformity Ratio as well as annual Indicators of daylight such as sDA and UDI. Zone 3 in the ground floor which is a space under top lit atrium acts as a source of daylight. Although, Zone 5 in the ground floor has reasonable daylight factor, the uniformity ratio is not acceptable due to simultaneously existing the areas of little and high illuminance. Zone 7 in the first floor as a public sapce can provide large potential for daylight utilization with DF equal to 2.6% and average WPI with 826 Lux because there is a possibility to receive daylight from east direction with designing central courtyard in the first floor plan.
Energy
A. Kamyab; M. Mahmoudi Zarandi; M. Nikpour
Abstract
Yazd is located in a hot-dry region with harsh weather conditions. Houses with an iwan were suitable for establishing comfort conditions in the past. An evaluation of the visual comfort conditions in residential courtyard buildings in Yazd city was carried out by investigating the effects of the depth ...
Read More
Yazd is located in a hot-dry region with harsh weather conditions. Houses with an iwan were suitable for establishing comfort conditions in the past. An evaluation of the visual comfort conditions in residential courtyard buildings in Yazd city was carried out by investigating the effects of the depth of the iwan and the ratio of the adjacent rooms' openings. Research is currently being conducted on an optimal model of the iwan in an effort to facilitate sustainable development and increase the use of such a model in contemporary housing. The effect of the parameters was investigated by simulating models containing different proportions of the iwan and sizes of the window in the Design Builder software. The results indicate that the proportion of the iwan and Window Wall Ratio of the adjacent room's window significantly affects the daylight that penetrates into the rooms. For the purposes of this study, climate-based daylight metrics (CBDMs), such as Useful Daylight Illuminances (UDI) with thresholds of 100–3000 lux and Spatial Daylight Autonomy (sDA) over 300 lux. In models with an iwan depth of 1.5 and above, windows from 20% to 60% WWR have the ability to bring a suitable amount of light into the room. This means that by using the iwan, wider windows can be designed without having glare and adding extra thermal load to the building. Results obtained from this research will provide new insight into the concepts of iwan. Furthermore, findings of this research help architect to design spaces with the utilization of daylight.
Energy
A. Kamyab; M. Mahmoodi Zarandi; M. Nikpour
Abstract
The city of Yazd has a large number of traditional houses. Houses with central courtyards and an Iwan were suitable for establishing thermal comfort conditions. In this research, the effect of Iwan's depth and the ratio of the adjacent room's openings on the comfort condition in the residential courtyard ...
Read More
The city of Yazd has a large number of traditional houses. Houses with central courtyards and an Iwan were suitable for establishing thermal comfort conditions. In this research, the effect of Iwan's depth and the ratio of the adjacent room's openings on the comfort condition in the residential courtyard buildings in Yazd city were evaluated. The current research aims to provide an optimal model of the Iwan to increase sustainable development and use such models as the Iwan in contemporary housing in the hot and dry climate of Yazd. In order to investigate the effect of parameters, samples from the north-facing room and south-facing room in a central courtyard model with different proportions of the Iwan and different sizes of the window were simulated in Design Builder software. The results showed that the depth of Iwan and window to wall ratio's (WWR) of the adjacent room’s window significantly affects the comfort (according to cooling load, heating load, and energy consumption) in this room. The results obtained in this research will be a new window to recover the concepts of old patterns and help to solve climate problems.
Energy
N. Tayari; M. Nikpour
Abstract
New designing techniques have been used recently in design phases of buildings to adapt human thermal comfort. Due to wide range of energy consumption within a building, it is impossible to make a proper decision about the impact of different energy efficiency strategies without simulation tools. Architects ...
Read More
New designing techniques have been used recently in design phases of buildings to adapt human thermal comfort. Due to wide range of energy consumption within a building, it is impossible to make a proper decision about the impact of different energy efficiency strategies without simulation tools. Architects need to understand the accuracy and precision of simulation software to use them as valuable tools to predict energy consumption. This research aims to investigate the validity of DesignBuilder simulation software by using the actual traditional house in terms of heat gain. In this study, the comparative method was used to determine the differences in heat gain in a traditional courtyard house in Kerman that was simulated using DesignBuilder software and measured experimentally. This study also reveals that the difference between simulation results and empirical measurement is not more than 10%. It can be concluded that DesignBuilder has enough validity to calculate the amount of heat gain in the rooms adjacent to courtyards.
Energy
N. Tayari; M. Nikpour
Abstract
Most of the spaces in contemporary houses in Iran cannot achieve enough daylight during daytime. Daylight utilization has a significant impact on decreasing energy consumption in residential buildings. Residents are deprived of natural daylight when there is no attention to the design based on daylight. ...
Read More
Most of the spaces in contemporary houses in Iran cannot achieve enough daylight during daytime. Daylight utilization has a significant impact on decreasing energy consumption in residential buildings. Residents are deprived of natural daylight when there is no attention to the design based on daylight. Iranian traditional architects use practical and straightforward methods in constructing courtyards houses to provide comfort conditions in unique rooms in courtyard houses in terms of daylight quality. In this research, the daylight quality of five separate rooms around the courtyard of Yazdanpanah's house was investigated through an experimental method. Average work plane illuminance and uniformity ratio were calculated in these rooms of the house in Kerman city, located in Iran's hot and dry climate. Findings of this research demonstrated that all rooms surrounding the courtyard of traditional houses have the ability to achieve work plane illuminance of more than acceptable value. Among all rooms around the central courtyard, one room facing the south direction achieves more than 500 Lux work plane illuminance. The amount of uniformity in this room is acceptable with more than 0.5 on most of the days in a year. The findings of this research could be used to design more comfortable rooms in contemporary houses in terms of daylight quality by creating central courtyards.
Energy
N. Tayari; M. Nikpour
Abstract
One of the crucial issues in early stages of designing process of a building is a lack of architects’ knowledge about the energy consumption in different forms of building with different proportions, especially in central courtyard forms. The purpose of this research is to investigate the effectiveness ...
Read More
One of the crucial issues in early stages of designing process of a building is a lack of architects’ knowledge about the energy consumption in different forms of building with different proportions, especially in central courtyard forms. The purpose of this research is to investigate the effectiveness of the ratio of perimeter to the height of the courtyard (R1) and the ratio of width to length of the courtyard (R2) on energy consumption. In the first step of this research, different proportions of central courtyard with different R1 and R2 were simulated in design builder software. Then, multi linear regression was used to find out the effect of different proportions (R1 and R2) on energy consumption through SPSS software. Finally, the effect of R1 and R 2 ratio on energy consumption was validated through investigating six existing central courtyard forms. The result demonstrated that the effective coefficient of the R1 and R2 ratio on energy consumption were -25.41 and 62.69 respectively. Findings of this research help architects to achieve relative acknowledge about the energy consumption of different proportions of the courtyard forms for creating more energy efficient forms.